meta data for this page
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| sector:natural_sources:forest_fires:start [2022/09/22 10:54] – Fix text tarakji | sector:natural_sources:forest_fires:start [2024/11/06 14:47] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 97: | Line 97: | ||
| - | ^ ^ 1990 ^ 1991 ^ 1992 ^ 1993 ^ 1994 ^ 1995 ^ 1996 ^ 1997 ^ 1998 ^ 1999 | + | ^ 1990 |
| - | | Area of forest burnt | + | | |
| - | + | ^ | |
| - | + | | | |
| - | + | ^ | |
| - | ^ | + | | |
| - | | Area of forest burnt | + | ^ 2020 |
| - | + | | | |
| - | + | ||
| - | ^ | + | |
| - | | Area of forest burnt | 269 | | + | |
| Line 113: | Line 110: | ||
| ==== Emission factors ==== | ==== Emission factors ==== | ||
| + | For the year 2020 the following estimated emission factors were applied: | ||
| - | For the year 2020 the estimated emission factors from table 2 were applied. | + | __Table 2: Emission factors applied for 2020, in [kg/ha forest area burnt]__ |
| - | + | ^ ^ EF< | |
| - | __Table 2: Emission factors applied for 2020__ | + | | NO< |
| - | ^ | + | | CO | 4, |
| - | | NO< | + | | NMVOC |
| - | | CO | | + | | SO< |
| - | | NMVOC | + | | NH< |
| - | | SO< | + | | TSP |
| - | | NH< | + | | PM< |
| - | | TSP | + | | PM< |
| - | | PM< | + | | BC | 34.01 | |
| - | | PM< | + | |
| - | | BC | 34.01 | | + | |
| In addition, a large-scale fire, which occurred in September 2018, is reported under 11.B. A detailed description can be found in the NIR | In addition, a large-scale fire, which occurred in September 2018, is reported under 11.B. A detailed description can be found in the NIR | ||
| 2020 in Chapter 6.8.2.5 ((NIR (2020): National Inventory Report 2020 for the German Greenhouse Gas Inventory 1990-2018. Available in April 2020)), because a large amount of CO< | 2020 in Chapter 6.8.2.5 ((NIR (2020): National Inventory Report 2020 for the German Greenhouse Gas Inventory 1990-2018. Available in April 2020)), because a large amount of CO< | ||
| - | The burned area of the drained moor, which is used as a military facility, covered 1,221 ha. This fire was extensively investigated and documented by the Federal Office for Infrastructure, | + | The burned area of the drained moor, which is used as a military facility, covered 1,221 ha. This fire was extensively investigated and documented by the Federal Office for Infrastructure, |
| - | )). | + | |
| + | The product M< | ||
| + | |||
| + | <WRAP center round info 60%> | ||
| + | * M< | ||
| - | The product MB×Cf is set to 336 t dm ha-1 according to Table 2.6 and formula 2.7 2013 IPCC Wetlands Supplement ((IPCC (Intergovernmental Panel on Climate Change) (2014b): 2013 Supplement to the IPCC Guidelines for National Greenhouse Gas Inventories: | + | * C< |
| + | </WRAP> | ||
| - | For the calculation of CO emissions the EF according to Table 2.7, 2013 IPCC Wetlands Supplement 207 g (kg dm)< | + | For the calculation of CO emissions the EF according to Table 2.7, 2013 IPCC Wetlands Supplement 207 g (kg dm)< |